Шинопроводи
Busbar KAM: 25A / 32A / 40A
Plug-in type designed to feed lighting luminaries.
- 25 / 32 / 40A
- Prewired plugs
- Tap-off points every 75cm
- 5 or 4 conductors for 3 phase-applications,3 conductors for single phase applications
- Copper conductors, continuously tin plated
- Electrical and mechanical joints are single bolt construction
- IP55
Busbar KAP: 40A up to 63A
Plug-in type designed for distribution of electricity in small scale enterprises.
- 40 / 63A
- prewired plugs
- tap-off points every 75cm
- 5 or 4 conductors for 3phase applications
- copper conductors, continiously tin plated
- electrical an mechanical joints are single bolt construction
- Tap-off boxes (3f+N) with fuses or MCB
- IP55
E-Line KO-II
Busbar KO: 160A up to 800A
Provides economical solutions for transmission and distribution of electricity in medium-scaled buildings and industrial facilities.
- 160A / 250A / 315A / 400A / 500A / 630A / 800A
- 4, 4.5 or 5 conductors
- selection of aluminium or copper conductors
- note: 800A only in copper
- conductors continiously tin plated
- tap-off points every 50cm on both sides
- clean earth option
- IP55
Busbar KX: 800A up to 6300A
New bolt-on or plug-in type designed for transmission and distribution of electricity in large scale installations and buildings. With improved characteristics.
Advantages of the E-line KX compact Busbar:
- high short circuit resistance due to compact construction
- lower voltage drop when compared to cable systems
- high mechanical resistance
- better cooling capability
- fast, easy and safe installation
Current rating for KXA (aluminium conductors):
800A / 1000A / 1250A / 1350A / 1600A / 2000A / 2500A / 3200A / 4000A / 5000A
Current rating for KXC (copper conductors):
800A / 1000A / 1250A / 1350A / 1600A / 2000A / 2500A / 3150A / 3600A / 3900A / 4250A / 5000A / 6300A
- 4, 4.5 or 5 conductors
- conductors continiously tin plated
- conductors continiously epoxy insulated
- clean earth option
- aluminium housing with RAL 7038 colour as standard
- IP 55
Busbar DL: 25A / 32A / 40A
Plug-in type with an independant double sided circuit, designed to feed lighting luminaries. Enables the carrying of mains and emergency lighting energy within the same body.
- 25 / 32 / 40A
- prewired plugs
- tap-off points every 75cm on both sides
- combinations of different number of conductors:
- 2+2, 2+4, 4+4, 3+3, 3+5, 5+5
- up to a maximum of 10 conductors (5+5)
- copper conductors, continiously tin plated
- electrical an mechanical joints are single bolt construction
- IP55
Busbar KB: 800A up to 6300A
Bolt-on or plug-in type system designed for transmission and distribution of electricity in large scale installations and buildings.
Current rating for KBA (aluminium conductors):
800A / 1000A / 1250A / 1600A / 2000A / 2500A / 3050A / 3100A / 4000A / 4250A
Current rating for KBC II (copper conductors):
1000A / 1250A / 1600A / 2000A / 2250A / 2500A / 3000A /3600A / 4250A / 4400A / 5300A / 6300A
- 4, 4.5 or 5 conductors
- conductors continiously tin plated
- clean earth option
- galvanized metal sheet body
- IP 55
E-Line MK
Busbar MK: 100A / 160A /225A
Plug-in type designed for transmission and distribution of electricity in small scale enterprises.
- 100 / 160 / 225A
- 4 or 5 conductors
- selection of aluminium or copper conductors
- note: 225A only in copper
- conductors continiously tin plated
- tap-off points every 50cm on both sides
- RAL 7038 painted steel enclosure
- IP55
E-Line CR
E-Line FL – FLD